Sonitus

Questions & answers

Answers to the questions we are asked most often: products, mounting, delivery and custom work.

Sonitus Acoustics

My room is noisy – when there are several of us we can't understand each other and have to shout. Why, and how do I fix it?

The room is noisy because sound bounces off hard surfaces (glass, concrete, tiles, plaster) and stays in the room instead of dying away. The fix is to add surfaces that absorb sound instead of reflecting it: acoustic panels.

When reverberation lasts too long, speech gets “smeared”: words overlap, so we understand each other less well and unconsciously start speaking louder. Then everyone else speaks louder too, and the noise keeps building. This is known as the Lombard effect, and it is the main reason why full cafés, restaurants, kindergartens and offices are so loud.

Acoustic panels shorten the reverberation time. The result is more than a few decibels less noise: speech is much easier to understand, people stop talking over each other, and the room feels calmer and more private. The same applies at home, in a living room with lots of glass and hard floors.

How much reverberation should my room have?

It depends on the use: the more speech intelligibility matters, the shorter the reverberation should be. It is measured as reverberation time (RT60): how many seconds it takes for sound to decay by 60 dB.

Room Reverberation time Basis
Control room, studio, hi-fi listening room 0.2 – 0.4 s EBU Tech 3276 recommendation
Home theater, voice recording, podcast 0.3 – 0.5 s common practice
Living room, home office 0.4 – 0.6 s common practice (not regulated)
Classroom, kindergarten room 0.45 – 0.6 s DIN 18041
Meeting room, lecture room 0.6 – 0.85 s DIN 18041
Open-plan office about 0.65 – 0.7 s DIN 18041
School cafeteria, kindergarten dining room about 0.55 – 0.6 s DIN 18041
Restaurant, café about 0.8 s at most; 0.5 – 0.7 s for comfortable conversation DIN 18041 and common practice
Waiting room, library, hospital room about 0.8 – 0.85 s DIN 18041
Entrance hall, counter hall about 1.05 – 1.15 s DIN 18041
Music room (rehearsal room, small hall) 0.95 – 1.2 s DIN 18041
Sports hall 1.4 – 2.0 s DIN 18041

DIN 18041 is the German standard for room acoustics; its values are calculated from the room volume, and the table shows typical ranges. In Croatia, the Technical Regulation on Acoustics in Buildings (Official Gazette NN 71/25), in force since April 2025, is built on it: for schools, kindergartens, halls, open-plan offices, waiting rooms, hospital corridors and entrance halls of public buildings the reverberation time is mandatory and has to be demonstrated in the building design. The requirements do not apply to rooms inside homes, and for restaurants and cafés professional recommendations apply. Other European countries have similar standards of their own.

For comparison: an empty room with hard surfaces easily has 1.5 s or more.

Will acoustic panels stop my neighbors from hearing me, or me from hearing them?

Mostly no. Acoustic panels improve the sound inside a room; sound that passes through a wall, ceiling or floor is stopped only by sound insulation (soundproofing).

These are two different jobs. Absorption reduces reverberation and noise within the room itself; it is done with light, porous materials. Sound insulation keeps sound from passing into the neighboring space; it takes mass, decoupled constructions and good sealing.

Noise between apartments travels in two ways:

  • Airborne noise: speech, music, the TV. It travels through the air and then through the wall or ceiling.
  • Impact noise: footsteps, chairs being moved, an object that falls. It is created by a blow to the structure and spreads through the floor, ceiling and walls.

Absorbers do not help against impact noise, and against airborne noise they help only a little. Room acoustics still matter, in both directions. In a reverberant room, noise coming in from the neighbors sounds louder than in an acoustically treated one. The reverse is also true: in a reverberant room your own sound is louder, so more of it gets through to the neighbors. The difference is a few decibels (when the reverberation time is halved, the noise level drops by about 3 dB). That is audible, but it does not solve the problem if the wall or ceiling is weak.

I can hear my upstairs neighbor. Can I cover the ceiling with absorbers and solve the problem?

No. Absorbers on the ceiling will not solve noise from the apartment above, for several reasons.

First, what usually bothers people is impact noise: footsteps, heels, furniture being moved. It travels through the structure itself, and a light, porous absorber has no effect on it.

Second, this kind of noise is best dealt with at the source, in the apartment above: with a floating floor or a soft floor covering (carpet, a resilient underlay beneath laminate).

Third, if that is not possible, what helps on your side is not absorption but added sound insulation: a suspended ceiling that is decoupled from the floor slab, with the cavity filled with dense absorbent material and closed with two layers of gypsum board.

Even that is no guarantee. Sound from the apartment above does not come only through the ceiling but also sideways, through the walls and the vertical parts of the structure. How much a suspended ceiling helps depends on how the building was built, so in an existing building the result cannot be predicted with certainty. As a rule it helps more against speech and music than against footsteps. Before a major investment, a measurement or advice from an acoustician is worth the money.

So how is additional sound insulation of a wall or ceiling done?

A new, heavy lining on its own frame is added in front of the existing wall or below the ceiling, and the cavity is filled with dense absorbent material. Gluing panels directly to the wall is not sound insulation.

The usual build-up, from the existing wall toward the room:

  1. The existing wall or ceiling.
  2. A frame, wood or metal. Ideally it touches the existing wall as little as possible (free-standing or on resilient mounts).
  3. Rebonded foam inside the frame, filling the cavity. It is available in densities from 60 to 140 kg/m³; for sound insulation the higher densities are chosen, because a heavier material damps the cavity better and adds mass to the lining.
  4. Two layers of gypsum board, or MDF boards, on the frame. More mass and two layers damp the resonance that a single thin board has.
  5. Sealing of all edges and joints all around. Even a small gap cancels much of the effect.
  6. The finish: a conventional wall finish (skim coat and paint) or an additional acoustic lining, for example thin PET panels. An acoustic lining also improves the acoustics of the room itself.

Insulating a wall is generally simpler and more predictable than insulating a ceiling. Caution applies here too: part of the sound bypasses the lining along flanking paths, through the adjoining walls, the floor and the ceiling.

Noise from the hallway or stairwell gets into my apartment. What can I do?

That noise most often comes in through the entrance door, so the door is the first place to fix. The second is the hallway itself.

A poor-quality, badly sealed entrance door lets through far more sound than the wall around it. If the hallway is also reverberant, with bare hard surfaces, sound that leaves one apartment through its door travels down the hallway almost undiminished to the door of the next apartment and gets in through it.

What helps:

  • The door: seals around the whole perimeter and a drop-down seal at the threshold, or a door with a declared sound insulation rating. For new buildings, the Croatian regulation requires entrance doors of at least 37 dB, or 30 dB if the apartment has a vestibule.
  • Absorbers in the hallway, on the ceiling or walls. They shorten the reverberation and reduce the noise carried along the hallway from door to door. The hallway is a shared part of the building, so the co-owners have to agree.
  • A vestibule inside the apartment, with a door to the living room, acts as an additional barrier.
Where should I place acoustic panels?

It depends on where the sound comes from. If the sources are everywhere (café, restaurant, office), spread the panels evenly around the room. If the source is in one place (loudspeakers in a listening room or studio), the panels go in precisely defined places.

Rooms with many people (cafés, restaurants, offices, classrooms). The noise sources are scattered and keep changing, so the absorption should be distributed too: on the ceiling and on at least two adjacent walls, not all on one surface. The ceiling is the most rewarding surface because it is large and free, and suspended ceiling absorbers in a single color hardly change the look of the room. Wall panels at head height and absorbers close to the tables further help intelligibility, because they catch sound close to where it is produced. Treating at least one of two bare, facing walls also removes the flutter echo between them. Since design matters in such rooms, the panels can be decoration as well: single-color or two-color PET panels with cut patterns, fabric-covered panels or linings with a wood finish.

Listening rooms, home theaters and studios. Here the source is fixed, so the first reflection points are treated first: the spots on the side walls and ceiling where sound from the loudspeakers bounces once before it reaches you. You can find them with a mirror: sit in the listening position while another person slides a mirror along the wall; where you see the loudspeaker in the mirror, that is where a panel goes. Next come the wall behind the loudspeakers and the wall behind the listener, and the corners of the room, where low frequencies build up. The layout should be symmetrical left and right.

Do I need to cover the whole room with absorbers?

No, and in most cases it is not even desirable. A room should keep some of its natural reverberation, otherwise it sounds unnatural, “dead” and tiring.

It is usually enough to treat a smaller share of the surfaces, but with effective absorbers. It is better to use fewer panels that absorb a wide range of frequencies and have a high absorption coefficient than to cover the whole room with thin material. Thin panels, carpets and curtains absorb almost only high frequencies: the room then loses its “air” and clarity, while the mid and low frequencies keep ringing. The result is a muddy, “boomy” sound, worse than before.

Example: for a 5 × 4 m room with a 2.6 m ceiling, about 10 to 13 m² of panels of the highest absorption class is usually enough. That is about 12 to 15% of the total area of the walls, ceiling and floor.

How many panels do I need?

Enough to bring the reverberation time down to a value that suits the use of the room. For most rooms that means covering roughly 10 to 25% of the total surface area with effective absorbers.

A more exact figure comes from the Sabine formula: reverberation time = 0.161 × volume / total absorption. The larger and “harder” the room, the more absorption it needs.

Example for a 5 × 4 × 2.6 m room (52 m³): empty, with hard surfaces, it has a reverberation time of about 1.4 s. For 0.5 s it needs about 17 m² of absorption in total; the room itself provides about 6, so about 11 m² is missing. That is about 12 m² of class A panels (αw 0.90), or about 18 m² of class C panels (αw 0.60). Furniture, carpet and people also absorb sound, so a furnished room needs less.

We are also preparing a reverberation time calculator: you enter the dimensions and surfaces, choose the panels and see the result right away.

Can I measure the acoustics of my room myself?

Yes: quite well for orientation, and with a little equipment fairly accurately too.

  • A hand clap. If after a clap you hear a long “ringing” or a metallic flutter between two walls, the room has too much reverberation. A quick test, without numbers.
  • A phone app. Apps for measuring reverberation time give a rough RT60 value, enough for a before-and-after comparison.
  • A measurement microphone and a computer. The free program Room EQ Wizard (REW), used with a measurement microphone, shows the reverberation time by frequency and the frequency response at the listening position. It is the standard for listening rooms and home studios.

For public spaces and projects with mandatory values, the measurement is done by an acoustician in accordance with ISO 3382. A measurement is always more accurate than a calculation, and a calculation is good for planning before you buy.

Which acoustic element do I need, and when?

It depends on which frequencies you want to tame. No panel absorbs all frequencies equally, so the elements are chosen by the range in which they work.

  • Porous absorbers: acoustic foam, melamine foam, PET felt, fabric-covered panels. They work on mid and high frequencies; the more material they have in their thickness, the lower they reach. Thicker panels (5 cm and more) are broadband and the basic choice for speech and for calming a room in general.
  • Absorbers with a perforated or slotted wooden front panel. They work on the resonator principle and are strongest in the mid range, and they are decorative as well. They pair well with porous absorbers.
  • Bass traps. Thick or specially tuned absorbers for low frequencies, most often placed in corners. Music rooms, home theaters and studios need them.
  • Thin absorbers: curtains, carpets, thin felt. They absorb only high frequencies; useful as a supplement, not as the only solution.
  • Diffusers. They do not absorb sound but scatter it; they are used when the room should stay lively.

Balance matters. If you dress the room only in thin absorbers or curtains, you will take out the high frequencies while the mid and low ones keep ringing; the room becomes muddy and “dead”. So combine elements that cover different ranges.

What do αw and absorption classes A–E mean?

They rate how well a panel absorbs sound. The absorption coefficient runs from 0 (everything is reflected) to 1 (everything is absorbed), and αw is a single overall value for the whole panel, calculated from the measurements by frequency in accordance with ISO 11654.

Class αw
A 0.90 – 1.00
B 0.80 – 0.85
C 0.60 – 0.75
D 0.30 – 0.55
E 0.15 – 0.25

The class is good for a quick comparison, but it does not tell the whole story. Two panels of the same class can differ greatly at low frequencies, so for music, a home theater or a studio look at the absorption curve by frequency as well. In addition, the same panel has a different value depending on how it is mounted (directly on the wall or with an air gap), so always check which mounting the figure applies to.

The values on our pages were measured in a laboratory in accordance with ISO 354, and the product pages carry the curves and the test reports. Compare the absorption of our products or see all test reports under Downloads.

Do egg cartons, ordinary foam or carpet help?

Very little. Egg cartons absorb almost no sound: they are too thin and not porous, and they only partly scatter the very highest frequencies.

Carpet, curtains and ordinary packaging foam absorb high frequencies but not the mid and low ones, so the room becomes muddy rather than calmer. As a supplement they are fine; as the only solution they are not. Acoustic panels have measured absorption and a declared fire class, which you do not know for improvised materials, and flammable packaging foam on a wall is a risk as well.

I work from home and my voice echoes on video calls. What is the least I need to do?

A few panels near your desk are enough. The microphone picks up the reverberation of the room, so you need to calm the surfaces around you, not the whole room.

You gain the most from panels on the wall behind the monitor (the one you speak toward), on the wall behind you and, if possible, above the desk. Three to six panels of 5 cm or thicker usually make a clear difference. A carpet, curtains and a full bookshelf help too. Moving the microphone closer to your mouth further reduces the share of reverberation in the recording.

What does fire class B-s1, d0 mean, and does it matter to me?

It is the European rating of how a material behaves in a fire, according to EN 13501-1, and it matters for all public spaces.

The letter (A1 to F) says how much the material contributes to a fire: A1 and A2 are non-combustible, B is hard to ignite, and toward F materials burn more and more readily (F is easily flammable or untested). The s rating describes smoke (s1 the least, s3 the most), and d describes burning droplets (d0 none). B-s1, d0 therefore means a material that is hard to ignite, produces little smoke and no burning droplets.

For hospitality venues, schools, offices and hotels, the required class is set by regulations and by the fire protection design, so check it with your designer before ordering. The fire class is stated in the specifications and technical data sheets of our products; it differs by material, thickness and sometimes by color.

How are the panels mounted, and can I do it myself?

Yes, most panels are easy to mount and need no special tools.

The most common methods are gluing with mounting adhesive, a magnetic system (the panels can be taken down and moved), mounting profiles for hanging on the wall, and suspension on wires below the ceiling, which also provides the air gap that improves absorption. Lightweight foam and PET felt panels can be cut with a utility knife, so they are easy to fit around sockets and corners.

Before gluing, check the surface (clean, dry, sound) and mark the panel layout in pencil. See the Acoufix adhesive and the magnetic mounting system.

F, M & V Series Absorbers →

Is a thicker panel better, or the same panel spaced away from the wall? And does it matter how “solid” the foam is?

A thicker panel and a gap from the wall help in the same way: the panel absorbs lower frequencies better. With profiled foam, the thickness of the solid base beneath the profile matters just as much.

The reason is physical. A porous material absorbs best where the air particles move fastest, which is a quarter of a wavelength away from the wall. Right at the wall, a thin panel “sees” only short waves, that is, high frequencies.

Air gap. A 12 mm PET panel glued to the wall has αw 0.30 (class D); the same panel suspended 200 mm below the ceiling has αw 0.80 (class B). That is why suspended ceiling panels and panels on spacers are so effective.

The base of profiled absorbers. With pyramids, cuboids and waves, the overall height does not tell the whole story. Two pyramid absorbers with an overall thickness of 7 cm can have a solid base of 2 cm or of 5 cm; the one with the 5 cm base has far more material and absorbs mid and lower-mid frequencies considerably better. Our absorber with an overall thickness of 4 cm and a 2 cm base absorbs about 20% of the sound at 250 Hz, while the 8 cm model with a solid 4 cm base absorbs about 55%. Had the thicker model kept the 2 cm base, the difference at 250 Hz would be much smaller.

So when you compare absorbers, always look at the base thickness too, not just the overall height. For the lowest frequencies even thick panels are not enough; that is where bass traps come in.

Diffusers →

What is the difference between an absorber and a diffuser, and when do I need diffusers?

An absorber soaks up sound, while a diffuser scatters it in many directions. An absorber shortens the reverberation; a diffuser breaks up strong individual reflections and leaves the room lively.

Diffusers make sense where the sound itself is the goal: listening rooms, studios, rehearsal rooms, concert and multipurpose halls. They typically go on the rear wall or the ceiling, behind the listening position, so that the sound stays spacious without being harsh. In a room that is simply too loud (café, office, classroom), absorbers come first; diffusers do not reduce noise.

Good treatment of a music room almost always combines both: absorption at the first reflections and in the corners, diffusion behind the listener.

Bass Traps →

Do I need bass traps?

You do if you listen to or record music in the room, or have a home theater. For speech, offices and hospitality spaces you generally do not.

In small rooms, low frequencies (roughly below 200 to 300 Hz) create standing waves: in some spots the bass “booms”, in others it disappears. Ordinary panels do not help there because they are too thin for such long waves. Bass traps are thick or specially tuned absorbers, and they are most effective in corners, where low frequencies build up, ideally from floor to ceiling.

Start with the corners behind the loudspeakers, then add the others. The effect is best seen by measuring before and after.

Did not find your question? Ask us →